Journal of Cutaneous and Aesthetic Surgery
Print this page
Email this page
Small font size
Default font size
Increase font size
Home About us Current issue Archives Instructions Submission Subscribe Editorial Board Partners Contact e-Alerts Login 
ORIGINAL ARTICLE
Year : 2013  |  Volume : 6  |  Issue : 4  |  Page : 189-193

Melanin index in assessing the treatment efficacy of 1064 nm Q switched Nd-Yag laser in nevus of Ota


1 Department of Dermatology, All India Institute of Medical Sciences, New Delhi, India
2 Department of Biostatistics, All India Institute of Medical Sciences, New Delhi, India

Correspondence Address:
Gomathy Sethuraman
Department of Dermatology, All India Institute of Medical Sciences, New Delhi-110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-2077.123398

Rights and Permissions

Background: Q-switched neodymium-yttrium aluminium-garnet (Q switched Nd-Yag) laser has been used in the treatment of nevus of Ota in all skin types with variable success rate. Data with an objective assessment parameter to this laser treatment is lacking. Objective: To evaluate the utility of melanin index in assessing the treatment response and also determine the efficacy and safety of the Q-switched Nd-Yag laser (1064-nm) in the treatment of nevus of Ota in Fitzpatrick skin types IV and V. Materials and Methods: A total of 35 patients treated with Nd-Yag laser were studied. The objective improvement (pigment clearance) was determined by melanin index from two fixed points: A1, 2 cm below the pupil at the mid pupillary line (when the gaze is fixed); A2, the most prominent part of zygoma. The melanin index in these two areas was recorded as M1 and M2, respectively. The subjective clinical improvement was determined by the physician and the patient global assessment score. Results: The mean baseline melanin indices M1 and M2 were 59.54 ± 9.72 and 59.02 ± 9.16, respectively. At the last visit the mean M1 and M2 decreased to 53.8 ± 8.55 (P < 0.001) and 54.13 ± 6.01 (P < 0.001), respectively. Patient and the physician global assessment score showed that 26 (74.3%) and 20 (57.14%) patients, respectively, had >50% pigment clearance. Conclusion: The melanin index, a simple non-invasive parameter is useful in assessing the treatment response more objectively. The 1064-nm Q-switched Nd-Yag laser offers good improvement in patients with nevus of Ota in darker skin types IV/V.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed5260    
    Printed49    
    Emailed0    
    PDF Downloaded247    
    Comments [Add]    

Recommend this journal